Item(s) you searched for "2141117119"

Products Found (11)



More Results (10)

Increasing building efficiency with insulating pipe support

...combined with the Bifix® G2 clamps to support the steel pipes up to an outer diameter of 141mm. For the pipes with a larger diameter than 141mm, Walraven Heavy Duty 500 clamps were selected. Thanks to the insulating pipe support, the noise travelling...

Read more

"Walraven made this complex project feel seamless thanks to perfect collaboration.”

...The Ensemble in Amsterdam was a challenging project—not only because of its height (119 meters) but also because of the technical requirements for installing solar panels on two towers. From the start, Walraven worked hand in hand with us at Energy...

Read more

Seamless collaboration for sustainable energy on a roof

...project Walraven has contributed to to date. The 119-metre-high project, The Ensemble, consists of two towers and a plinth roof (the lower part of the building). Walraven engineers designed a robust triangular frame structure for solar panels...

Read more

RLT - Air handling and cooling systems safely installed on flat roofs

...access to the technology and guarantee simple and safe maintenance. ‘The access points to the maintenance elements of flat-roof installations must meet certain standards, such as DIN EN 14122-2. They should be easy to walk on without risk of injury... pipe support technology inside the building. They must meet specific standards, such as DIN EN 14122-2. They should be easy to walk on without risk of injury,’ says Strobel. Do you have a question? Contact our expert! ...

Read more

How to choose suitable vibration isolators for outside AC splits?

...% 66,8% 81,0% 90,1% 93,9% 2801400750 450 45 2,4 401,6% -40,6% 40,3% 64,9% 80,1% 89,7% 93,6% 550 55 2,9 646,5% 8,4% 55,9% 73,0% 84,3% 91,7% 94,9% 750 75 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3% 2801401170 1000 100 3,4 2193,9% 30,4...% 64,4% 77,7% 86,8% 93,0% 95,6% 1170 117 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3% 2801401690 1200 120 2,8 578,7% 2,5% 53,8% 71,9% 83,7% 91,4% 94,7% 1500 150 3,6 9082,1% 34,7% 66,2% 78,7% 87,3% 93,3% 95,8% 1690 169 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3%...

Read more

How to choose suitable vibration isolators for inline fans and equipment?

...% 78,3% 87,1% 93,1% 95,7% 2800800450 350 35 3,1 849,3% 17,9% 59,5% 74,9% 85,3% 92,2% 95,2% 400 40 3,6 10443,2% 34,9% 66,2% 78,7% 87,4% 93,3% 95,8% 450 45 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3% Walraven VibraTek® SA-3 Walraven...% 79,4% 89,4% 93,4% 250 25 2,9 633,0% 7,4% 55,5% 72,8% 84,2% 91,7% 94,8% 300 30 3,5 4077,4% 33,1% 65,5% 78,3% 87,1% 93,1% 95,7% 2800800450 350 35 3,1 849,3% 17,9% 59,5% 74,9% 85,3% 92,2% 95,2% 400 40 3,6 10443,2% 34,9% 66,2% 78,7% 87,4% 93,3% 95,8% 450 45 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3%...

Read more

How to choose suitable vibration isolators for ventilation ducts?

...% 65,5% 78,3% 87,1% 93,1% 95,7% 2800800450 350 35 3,1 849,3% 17,9% 59,5% 74,9% 85,3% 92,2% 95,2% 400 40 3,6 10443,2% 34,9% 66,2% 78,7% 87,4% 93,3% 95,8% 450 45 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3% Walraven VibraTek...% 63,5% 79,4% 89,4% 93,4% 250 25 2,9 633,0% 7,4% 55,5% 72,8% 84,2% 91,7% 94,8% 300 30 3,5 4077,4% 33,1% 65,5% 78,3% 87,1% 93,1% 95,7% 2800800450 350 35 3,1 849,3% 17,9% 59,5% 74,9% 85,3% 92,2% 95,2% 400 40 3,6 10443,2% 34,9% 66,2% 78,7% 87,4% 93,3% 95,8% 450 45 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3%...

Read more

How to choose suitable vibration isolators for suspended piping systems?

...,5 4077,4% 33,1% 65,5% 78,3% 87,1% 93,1% 95,7% 2800800450 350 35 3,1 849,3% 17,9% 59,5% 74,9% 85,3% 92,2% 95,2% 400 40 3,6 10443,2% 34,9% 66,2% 78,7% 87,4% 93,3% 95,8% 450 45 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3% Walraven VibraTek...% -50,7% 37,5% 63,5% 79,4% 89,4% 93,4% 250 25 2,9 633,0% 7,4% 55,5% 72,8% 84,2% 91,7% 94,8% 300 30 3,5 4077,4% 33,1% 65,5% 78,3% 87,1% 93,1% 95,7% 2800800450 350 35 3,1 849,3% 17,9% 59,5% 74,9% 85,3% 92,2% 95,2% 400 40 3,6 10443,2% 34,9% 66,2% 78,7% 87,4% 93,3% 95,8% 450 45 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3%...

Read more

How to choose suitable vibration isolators for acoustic ceilings?  

...% 93,1% 95,7% 2800800450 350 35 3,1 849,3% 17,9% 59,5% 74,9% 85,3% 92,2% 95,2% 400 40 3,6 10443,2% 34,9% 66,2% 78,7% 87,4% 93,3% 95,8% 450 45 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3% Walraven VibraTek® SA-3 Walraven VibraTek...% 93,4% 250 25 2,9 633,0% 7,4% 55,5% 72,8% 84,2% 91,7% 94,8% 300 30 3,5 4077,4% 33,1% 65,5% 78,3% 87,1% 93,1% 95,7% 2800800450 350 35 3,1 849,3% 17,9% 59,5% 74,9% 85,3% 92,2% 95,2% 400 40 3,6 10443,2% 34,9% 66,2% 78,7% 87,4% 93,3% 95,8% 450 45 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3%...

Read more

How to choose suitable vibration isolators for compressors?

...% 2801800750 450 45 2,4 401,6% -40,6% 40,3% 64,9% 80,1% 89,7% 93,6% 750 75 4,0 -776,2% 46,0% 71,1% 81,5% 88,9% 94,1% 96,3% 2801801500 1000 100 3,7 -4599,3% 38,1% 67,6% 79,5% 87,8% 93,5% 95,9% 1500 150 5,5 -88,0% 65,8% 80,5% 87,2% 92,2% 95,7% 97,3...

Read more

Let's get in touch

Product wish list 0
To top
Close

International websiteOr visit our international website.